3,000 GPD industrial RO plant with two 4 × 40-inch membranes, 1.1 kW pump, 450 psi housings, dual TDS monitoring and automatic flush controls.

الوصف

Reverse osmosis capacity and operating design

This commercial and industrial RO plant is listed at a nominal production capacity of 3,000 GPD. Its product page lists 96–98% salt rejection and 50–60% recovery; actual output and rejection depend on feed-water temperature, TDS, pressure and operating conditions, so treat these as published design figures rather than guaranteed results for every water source.

Membranes, connections and pump

  • Two 4 × 40 inch RO membrane elements.
  • Connection sizes listed: 1 inch feed, 3/4 inch permeate and 3/4 inch concentrate.
  • Vertical stainless-steel multistage pump; the component list specifies 1.1 kW single-phase motor.
  • The page separately lists 1,120 W electricity consumption; confirm the rated input with the supplied nameplate.

Pretreatment and controls

  • Three 20-inch prefilters and a 5-micron sediment cartridge.
  • Membrane housings listed as stainless steel or fiberglass and rated to 450 psi.
  • Control panel with low-pressure alarm, dual TDS monitoring, feed flush, tank-level input and pressure switches.
  • Feed and flush solenoid valves, pressure regulator, inlet and concentrate flow meters, pressure gauges and clean-in-place (CIP) ports.
  • One anti-scalant dosing device is listed.

Before installation, confirm the feed-water analysis, pretreatment configuration, electrical supply, membrane brand and model, design pressure, and the 1.1 kW/1,120 W rating with Al Naqi Water. The page’s 200–400 psi wording is a general operating note for higher-TDS water; obtain the operating setpoint for this exact configuration.